# Change XYZ to the UID of your RS485 Bricklet

setup:
	# Set operating mode to Modbus RTU master
	publish '{"mode": "modbus_master_rtu"}' to tinkerforge/request/rs485_bricklet/XYZ/set_mode 
	
	# Modbus specific configuration:
	# - slave address = 1 (unused in master mode)
	# - master request timeout = 1000ms
	publish '{"slave_address": 1, "master_request_timeout": 1000}' to tinkerforge/request/rs485_bricklet/XYZ/set_modbus_configuration 
	
	# Handle incoming Modbus master write single register response callbacks
	subscribe to tinkerforge/callback/rs485_bricklet/XYZ/modbus_master_write_single_register_response
        if a message arrives
            # message contains request_id as int and exception_code as int with symbols
            print request_id
            if exception_code != "Timeout
                print exception_code
            endif
        endif
	endsubscribe
	publish '{"register": true}' to tinkerforge/register/rs485_bricklet/XYZ/modbus_master_write_single_register_response
	
	# Write 65535 to register 42 of slave 17
	publish '{"slave_address": 17, "register_address": 42, "register_value": 65535}' to tinkerforge/request/rs485_bricklet/XYZ/modbus_master_write_single_register 